<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Studies in Medical Sciences</title>
<title_fa>مجله مطالعات علوم پزشکی</title_fa>
<short_title>Studies in Medical Sciences</short_title>
<subject>Medical Sciences</subject>
<web_url>http://umj.umsu.ac.ir</web_url>
<journal_hbi_system_id>37</journal_hbi_system_id>
<journal_hbi_system_user>journal37</journal_hbi_system_user>
<journal_id_issn>2717-008X</journal_id_issn>
<journal_id_issn_online>2717-008X</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/umj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1398</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2019</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>30</volume>
<number>8</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مطالعه تحلیلی تأثیر پوشش دولایه معدنی و آلی اطراف نانوذرات اکسید آهن در کنتراست تصویربرداری تشدید مغناطیسی</title_fa>
	<title>ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST</title>
	<subject_fa>فیزیک پزشکی</subject_fa>
	<subject>Medical Physics</subject>
	<content_type_fa>پژوهشي(توصیفی- تحلیلی)</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;&lt;span style=&quot;font-family:nazanin;&quot;&gt;&lt;span style=&quot;font-size:9.5pt;&quot;&gt;پیش&#8204;زمینه و هدف: &lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:nazanin;&quot;&gt;&lt;span style=&quot;font-size:9.5pt;&quot;&gt;در سال&#8204;های اخیر، نانوذرات اکسید آهن به&#8204;منظور تقویت کنتراست تصویربرداری تشدید مغناطیسی &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;(MRI)&lt;/span&gt;&lt;span style=&quot;font-family:nazanin;&quot;&gt;&lt;span style=&quot;font-size:9.5pt;&quot;&gt; در تشخیص طیف وسیعی از بیماری&#8204;ها به&#8204;کاررفته&#8204;اند. نکته مهم در کاربرد این نانوذرات، استفاده از پوشش آلی یا معدنی اطراف نانوذرات جهت ایجاد زیست سازگاری و جلوگیری از سمیت آن&#8204;ها است. هدف از این مطالعه بررسی تأثیر پوشش دولایه معدنی (آلومینوسیلیکات) و آلی (پلی&#8204;اتیلن گلیکول) اطراف نانوذرات اکسید آهن در کنتراست تصویربرداری تشدید مغناطیسی است.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-family:nazanin;&quot;&gt;&lt;span style=&quot;font-size:9.5pt;&quot;&gt;مواد و روش&#8204; کار&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:nazanin;&quot;&gt;&lt;span style=&quot;font-size:9.5pt;&quot;&gt;: نانو کامپوزیت اکسید آهن- آلومینوسیلیکات- پلی&#8204;اتیلن گلیکول با اندازه 200-170 نانومتر تهیه شد. تصویربرداری تشدید مغناطیسی برای غلظت&#8204;های مختلف نانو کامپوزیت با استفاده از زمان&#8204;های تکرار پالس یکسان و زمان&#8204;های اکوی متفاوت انجام گردید. میانگین شدت سیگنال&#8204;ها برحسب غلظت&#8204;های کاربردی اندازه&#8204;گیری و منحنی&#8204;های زمان&#8204;های آسایش اسپین- اسپین رسم شد. مقدار آسایش دهی عرضی با استفاده از شیب منحنی نرخ&#8204;های آسایش اسپین- اسپین به ازای غلظت به دست آمد.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-family:nazanin;&quot;&gt;&lt;span style=&quot;font-size:9.5pt;&quot;&gt;یافته&#8204;ها&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:nazanin;&quot;&gt;&lt;span style=&quot;font-size:9.5pt;&quot;&gt;: کاهش شدت سیگنال به ازای افزایش زمان اکو برای تمام غلظت&#8204;ها مشاهده شد. زمان آسایش اسپین- اسپین نیز با افزایش غلظت نانو کامپوزیت کاهش یافت. مقدار آسایش دهی عرضی که به&#8204;عنوان پارامتر بیان&#8204;گر کنتراست در تصویربرداری تشدید مغناطیسی است، &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;s&lt;sup&gt;-1&lt;/sup&gt;.mM&lt;sup&gt;-1&lt;/sup&gt;&lt;/span&gt;&lt;span style=&quot;font-family:nazanin;&quot;&gt;&lt;span style=&quot;font-size:9.5pt;&quot;&gt; 73/80 محاسبه شد.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-family:nazanin;&quot;&gt;&lt;span style=&quot;font-size:9.5pt;&quot;&gt;بحث و نتیجه&#8204;گیری&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:nazanin;&quot;&gt;&lt;span style=&quot;font-size:9.5pt;&quot;&gt;: نانوذرات اکسید آهن با پوشش دولایه آلومینوسیلیکات و پلی&#8204;اتیلن گلیکول، پتانسیل ایجاد کنتراست منفی در تصاویر تشدید مغناطیسی را به دلیل ساختار متخلخل پوشش معدنی آلومینوسیلیکات و پتانسیل استفاده در دارورسانی را با توجه به پوشش پلیمر آلی پلی&#8204;اتیلن گلیکول فراهم می&#8204;کنند.&lt;/span&gt;&lt;/span&gt;</abstract_fa>
	<abstract>&lt;a name=&quot;_Toc416081061&quot;&gt;&lt;strong&gt;&lt;em&gt;Background &amp; Aims&lt;/em&gt;&lt;/strong&gt;&lt;/a&gt;: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect of bilayer inorganic (aluminosilicate) and organic (polyethylene glycol) coating around the iron oxide nanoparticles on magnetic resonance imaging contrast.&lt;br&gt;
&lt;strong&gt;&lt;em&gt;Materials &amp; Methods&lt;/em&gt;&lt;/strong&gt;: Iron oxide- aluminosilicate- polyethylene glycol nanocomposite with the size of 170-200 nm was prepared. Magnetic resonance imaging for different concentrations of the nanocomposite was carried out by the use of similar repetition time and different echo times. Mean signal intensities were measured based on applied concentrations, and the curves of spin-spin relaxation times plotted. Transverse relaxivity value was obtained using the slope of spin-spin relaxation rate versus concentration.&lt;br&gt;
&lt;strong&gt;&lt;em&gt;Results&lt;/em&gt;&lt;/strong&gt;: Reduction of signal intensity with increasing echo time was observed for all concentrations. The spin-spin relaxation time decreased as a function of the concentration. The transverse relaxivity as a parameter to show magnetic resonance imaging contrast was calculated to be 80.73 s-1.mM-1.&lt;br&gt;
Conclusion: Iron oxide nanoparticles with bilayer aluminosilicate and polyethylene glycol coating can provide negative contrast for magnetic resonance images due to the porous structure of the aluminosilicate, and the possibility of using the nanocomposite for drug delivery according to the presence of polyethylene glycol.</abstract>
	<keyword_fa>تصویربرداری تشدید مغناطیسی, نانوذرات اکسید آهن, کنتراست, آلومینوسیلیکات, پلی‌اتیلن گلیکول</keyword_fa>
	<keyword>Magnetic resonance imaging, Iron oxide nanoparticles, Contrast, Aluminosilicate, Polyethylene glycol</keyword>
	<start_page>597</start_page>
	<end_page>608</end_page>
	<web_url>http://umj.umsu.ac.ir/browse.php?a_code=A-10-4097-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Nahideh</first_name>
	<middle_name></middle_name>
	<last_name>Gharehaghaji</last_name>
	<suffix></suffix>
	<first_name_fa>ناهیده</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قره آغاجی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>gharehaghajin@tbzmed.ac.ir</email>
	<code>3700319475328460032984</code>
	<orcid>3700319475328460032984</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Radiology, Faculty of Paramedicine, Tabriz University of Medical Sciences, Tabriz, Iran</affiliation>
	<affiliation_fa>گروه رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی تبریز، تبریز، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Baharak</first_name>
	<middle_name></middle_name>
	<last_name>Divband</last_name>
	<suffix></suffix>
	<first_name_fa>بهارک</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دیوبند</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>bdivband@gmail.com</email>
	<code>3700319475328460032985</code>
	<orcid>3700319475328460032985</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran (Corresponding Author)</affiliation>
	<affiliation_fa>مرکز تحقیقات لثه و دندان، دانشگاه علوم پزشکی تبریز، تبریز، ایران (نویسنده مسئول)</affiliation_fa>
	 </author>


	<author>
	<first_name>Zahra</first_name>
	<middle_name></middle_name>
	<last_name>Atashi</last_name>
	<suffix></suffix>
	<first_name_fa>زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آتشی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>atashizahra913@gmail.com</email>
	<code>3700319475328460032986</code>
	<orcid>3700319475328460032986</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی تبریز، تبریز، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
