<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Studies in Medical Sciences</title>
<title_fa>مجله مطالعات علوم پزشکی</title_fa>
<short_title>Studies in Medical Sciences</short_title>
<subject>Medical Sciences</subject>
<web_url>http://umj.umsu.ac.ir</web_url>
<journal_hbi_system_id>37</journal_hbi_system_id>
<journal_hbi_system_user>journal37</journal_hbi_system_user>
<journal_id_issn>2717-008X</journal_id_issn>
<journal_id_issn_online>2717-008X</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/umj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>36</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>توسعه روش میکرو استخراج فاز جامد با فیبر کربنی برای استخراج و پیش تغلیظ 1 و 4-دی‌اکسان از نمونه‌های آرایشی بهداشتی</title_fa>
	<title>Development of a Solid Phase Microextraction Method WITH Carbon Fiber for Extraction and Preconcentration of 1,4-Dioxane FROM Cosmetic SAMPLES</title>
	<subject_fa>داروسازی</subject_fa>
	<subject>داروسازی</subject>
	<content_type_fa>پژوهشي(توصیفی- تحلیلی)</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div&gt;
&lt;div style=&quot;border-right:solid #dddddd 2.25pt; padding:0in 0in 0in 0in; margin-right:15px&quot;&gt;&lt;strong&gt;پیش&#8204;زمینه و هدف:&lt;/strong&gt; 1 و 4-دی اکسان یک ترکیب اتر حلقوی است که به&#8204;عنوان حلال در واکنش&#8204;های شیمیایی استفاده می&#8204;شود. با توجه به خاصیت سرطان&#8204;زایی این ترکیب، کنترل و اندازه&#8204;گیری آن در محصولات آرایشی-بهداشتی و شوینده&#8204;ها از اهمیت بالایی برخوردار است.&lt;span style=&quot;font-family:Nazanin&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;مواد و روش کار:&lt;/strong&gt; در این پژوهش، یک روش میکرواستخراج فاز جامد (SPME) بر پایه فیبر کربنی اصلاح&#8204;شده برای استخراج و پیش تغلیظ 1 و 4-دی اکسان از نمونه&#8204;های آرایشی-بهداشتی توسعه داده شد. این روش با استخراج از فضای فوقانی (HS-SPME) تلفیق شد و آنالیز نهایی توسط دستگاه کروماتوگرافی گازی مجهز به دتکتور یونیزاسیون شعله&#8204;ای (GC-FID) انجام گرفت.&lt;br&gt;
&lt;strong&gt;یافته&#8204;ها:&lt;/strong&gt; حد تشخیص (LOD) و حد اندازه&#8204;گیری (LOQ) روش به ترتیب 4/0 و 2/1 میکروگرم بر کیلوگرم بود. محدوده خطی روش 5/1 تا 300 میکروگرم بر کیلوگرم را پوشش داد. انحراف استاندارد نسبی (RSD%) برای غلظت 25 میکروگرم بر کیلوگرم (n=6) برابر با 8/5درصد بود که نشان&#8204;دهنده دقت و تکرارپذیری مطلوب روش است. فیبر کربنی اصلاح&#8204;شده با آنیلین، پیرول و گرافن اکسید کارایی بالایی در استخراج 1 و 4-دی اکسان نشان داد.&lt;/div&gt;
&lt;strong&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:9.5pt&quot;&gt;بحث و نتیجه&#8204;گیری&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:9.5pt&quot;&gt;&lt;strong&gt;:&lt;/strong&gt; &lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot; style=&quot;font-size:9.5pt&quot;&gt;روش پیشنهادی &lt;/span&gt;HS-SPME/GC-FID &lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot; style=&quot;font-size:9.5pt&quot;&gt;با استفاده از فیبر کربنی اصلاح&#8204;شده، یک روش حساس، سریع و کم&#8204;حجم برای اندازه&#8204;گیری 1 و 4-دی اکسان در نمونه&#8204;های آرایشی-بهداشتی است. این روش از کروماتوگرام&#8204;های مطلوب، حد تشخیص پایین و انتخاب&#8204;گری مناسب برخوردار بوده و می&#8204;تواند برای پایش این آلاینده در محصولات مصرفی مورداستفاده قرار گیرد&lt;/span&gt;&lt;span style=&quot;font-family:Nazanin&quot;&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;strong&gt;&lt;a name=&quot;_Toc416081061&quot;&gt;&lt;/a&gt;&lt;/strong&gt;&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;background:#c6d9f1&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;a name=&quot;_Toc416081061&quot;&gt;&lt;b&gt;&lt;i&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;Background &amp; Aims: &lt;/span&gt;&lt;/i&gt;&lt;/b&gt;&lt;/a&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;1,4-Dioxane, a cyclic ether commonly employed in chemical and syntheses processes as a solvent, is now a probable human carcinogen. It is frequently found as a byproduct of detergents and personal care products, so reliable analytical methods to locate and quantify it in cosmetics are important for compliance, regulatory, and public health reasons. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;background:#c6d9f1&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;b&gt;&lt;i&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;Materials &amp; Methods:&lt;/span&gt;&lt;/i&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt; We developed an optimized headspace solid-phase microextraction (HS-SPME) method that has the modified carbon fiber as the extraction phase when coupled with GC-FID. The analytical method also allows us to take the best of liquid-liquid extraction and HS-SPME together for better sensitivity in cosmetic matrices. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;i&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;color:#333333&quot;&gt;Results&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/i&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;color:#333333&quot;&gt;: The method provided adequate sensitivity, detection limit (LOD) of 0.4 &amp;mu;g/kg and quantitation limit (LOQ) of 1.2 &amp;mu;g/kg. The linear dynamic range was 1.5-300 &amp;mu;g/kg, R&amp;sup2; &gt; 0.999, precision of 5.8% as RSD at 25 &amp;mu;g/kg, n=6. The carbon fiber modified with aniline/pyrrole/graphene oxide extraction phase had longer extraction times, but was more efficient than conventional fibers due to its &amp;pi;-&amp;pi; modified interactions as well as more areas of contact and surface hydrophobicity. &lt;b&gt;&lt;i&gt;Conclusion&lt;/i&gt;&lt;/b&gt;: This method for the headspace solid-phase microextration-gas chromatography-flame ionization detection (HS-SPME-GC-FID) provides a sensitive, reliable, and solvent free method for monitoring, locating, and quantifying 1,4-dioxane in cosmetics to comply with regulatory standards of monitoring carcinogens. The modified carbon fiber exhibits exceptional performance for trace-level extraction of this challenging analyte.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;</abstract>
	<keyword_fa>میکرواستخراج فاز جامد (SPME), 1 و 4-دی‌اکسان, محصولات آرایشی-بهداشتی, فیبر کربنی</keyword_fa>
	<keyword>Solid-phase microextraction (SPME), 1,4-Dioxane, Cosmetics samples, Carbon fiber</keyword>
	<start_page>63</start_page>
	<end_page>77</end_page>
	<web_url>http://umj.umsu.ac.ir/browse.php?a_code=A-10-2460-6&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Behrang</first_name>
	<middle_name></middle_name>
	<last_name>Hamze-Khalifani</last_name>
	<suffix></suffix>
	<first_name_fa>بهرنگ</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حمزه خلیفانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>3700319475328460037429</code>
	<orcid>3700319475328460037429</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Ph. D. in Pharmacy, School of Pharmacy, Urmia University of Medical Sciences, Urmia, Iran</affiliation>
	<affiliation_fa>دکتری عمومی داروسازی، دانشکده داروسازی، دانشگاه علوم پزشکی ارومیه، ارومیه، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Reza</first_name>
	<middle_name></middle_name>
	<last_name>Vardast</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>وردست</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mrvardast@gmail.com</email>
	<code>3700319475328460037430</code>
	<orcid>3700319475328460037430</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Assistant Professor of Medicinal Chemistry, School of pharmacy, Urmia University of Medical Science, Urmia, Iran (Corresponding Author)</affiliation>
	<affiliation_fa>استادیار گروه شیمی دارویی، دانشکده داروسازی، دانشگاه علوم پزشکی ارومیه، ارومیه، ایران (نویسنده مسئول)</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
